Practical Information. Professional Standards
Flow rate and skin contact guide
■ We tested the pumps with the patient connector kept at 23°C instead of 32°C, as you see, 32°C is the standard test condition specified in our procedure and IFU. Under this condition, the flow rate …
Crystallization Mechanism of 5-FU (5-Fluorouracil)_En
Please refer to file attached, ” Crystallization Mechanism of 5-FU (5-Fluorouracil)_En”
Why Does 5-FU occlude Infusion Pumps?
Please refer to file attached, Why Does 5-FU occlude Infusion Pumps ?
Flow rate color code
The Neofuser Onco series is standardly shipped with these color-coded labels to ensure consistent quality and ease of use. We use color-coded labeling based on flow rates. Each flow rate is assigned …
Electronic Infusion Pump vs. Elastomeric Infusion Pump
Electronic infusion pumps require electrical power and programmable settings, making them suitable for closely monitored hospital environments. Elastomeric infusion pumps operate without electricity,…
Product Volume Range
Product Volume Range The table below shows the available volume range for each product model.Please refer to the minimum and maximum infusion capacities.
Micro-channel for oncology application, flow rate formula
Please refer to the file attached, it shows the formula of flow rate. As we increased the diameter of the capillary by 4.6 times, we had to make its length 28 times longer. We developed a micro-chann…
🔗 Neuraxial Connector (ISO 80369-6) ?
🔗 Neuraxial Connector (ISO 80369-6) A Neuraxial Connector is a patient-safety–engineered connector designed exclusively for neuraxial applications such as epidural and spinal (intrathecal) drug deli…
🔬 Silicone vs. Isoprene: The Science Behind Drug Stability
🔬 Silicone vs. Isoprene: The Science Behind Drug Stability ■ Isoprene: Organic (Hydrocarbon-Based) Chemical Formula: C₅H₈ A hydrocarbon molecule composed only of carbon (C) and hydrogen (H). Classif…
💉 Why Do We Need Microchannels for Chemotherapy Drug Delivery?
In elastomeric infusion pumps, flow rate is typically controlled using a capillary—a very small tube with an internal diameter of approximately 50 µm and a length of about 15 mm. However, this design…
The most important factors in Elastomeric infusion pumps
Please read ” The most important factors in Elastomeric infusion pumps”
💡 Why Precise Flow Rate Matters in Chemotherapy ?
In chemotherapy, accuracy in drug delivery is critical. Elastomeric infusion pumps must deliver medication not just over a certain duration, but at a consistent flow rate every hour. When flow rates …